6 Performing Measurement and Adjustment
6 - 14
Vision System FH/FHV/FZ5 Series Users Manual (Z365)
6 When you use the function to switch the saving folder, set the switching conditions.
[Save to Memory + File] Setting Example and Save Destination
[Save to Memory + FTP Server] Setting Example and Save Destination
Setting item Set value [Factory default] Description
Switch saving
folder by scene
Checked
[Unchecked]
If this is checked, folders that correspond to scene numbers
are automatically created and image files are divided by
scene and saved.
Use scene name
as folder names
Checked
[Unchecked]
If this is checked, folders to which image files are allocated
are named using the scene names and scene group names
at the time of measurement execution.
If a scene name contains a character not supported for folder
names, a logging error is generated when logging is exe-
cuted.
The following symbols can not be used in the file or folder
names.
¥ / : , ; * ? " < > |
If these symbols are used, a logging error is generated when
logging is executed.
Switch saving
folder by judge
Checked
[Unchecked]
If this is checked, OK/NG folders are automatically created
and image files are divided by the overall judgment and
saved.
Setting example Destination
Folder name: USB disk
Prefix: image_
[Switch saving folder by scene]: Selected
[Switch saving folder by judge.]: Selected
The settings in the example on the left are applied as
shown below.
OK image save destination:
\USBDisk\S000-000\OK\image_(Measurement
ID).IFZt
NG image save destination:
\USBDisk\S000-002\NG\image_(Measurement
ID).IFZ
Setting example Destination
IP address: 10.5.6.100
User name: OMRON
Password: abc
Port number.: 21
Connection method: Active
Folder name: Logging
Prefix: image_
[Switch saving folder by scene]: Selected
[Switch saving folder by judge]: Not selected
With left sample settings, the file will be saved as below.
When the current directory which FTP server specifies
is "C:\Data\RAMDisk".
C:\Data\RamDisk\Logging\S000-000\image_(Mea-
surement ID.ifz)