6 - 13
6 Performing Measurement and Adjustment
Vision System FH/FHV/FZ5 Series User’s Manual (Z365)
6-3 Useful Functions for Operation
6
6-3-1 Logging Measurement Values and Measurement Images [Data Logging/Image Logging]
In order to perform logging quickly, image files are first saved in the Controller memory (RAM).
The Controller memory (RAM) for saving images is a ring memory.
Refer to A-7 About Number of Logging Images on page A-23.
If power of the Controller is turned OFF or it is restarted, the data saved in the Controller mem-
ory or RAM Disk will be cleared.
Select [Save to memory + file] or [Save to memory + FTP Server] to save them in external stor-
age.
When [Save to memory + file] in [Destination] is selected, set the destination and file names.
If you select [Save to memory + FTP Server] as a [Destination], configure the setting items
below.
5 Specify the prefix of the image logging file.
Parameter Set value [Factory default] Description
Folder name • [RAM Disk]
• Drive name of external
storage device
Specify the image file save destination (RAM disk or external
storage). Logged images are saved in the specified save
destination folder. (Maximum number of characters: 128 sin-
gle-byte characters)
Setting item Set value [Factory default] Description
IP address a.b.c.d
a: 1 to 223
b: 0 to 255
c: 0 to 255
d: 0 to 255
[1.0.0.0]
Specify the IP address of the destination FTP server.
Connection via a proxy server cannot be made.
User name [Anonymous] Specify the user name which is used for a connection with the
destination FTP server. Use only single-byte alphanumeric
characters and numbers.
Password
---
Enter the password for a connection with the destination FTP
server.
Port number [21] Enter the port number for a connection with the destination
FTP server.
Connection
method
• [Active]
• Passive
Select the FTP connection method.
Folder name
---
Specify the destination directory of the FTP server. Use the
relative pathname of the destination directory.
Use only single-byte alphanumeric characters and numbers.
Setting item Set value [Factory default] Description
Prefix
---
Set the prefix for the saved file name. (Maximum number of
characters: 32 single-byte characters)
The set character string is added at the beginning of the
name of the save file. Use only single-byte alphanumeric
characters and numbers.
If a prefix contains a non-supported character, a logging error
is generated when logging is executed.