8 Setting Windows
8 - 54
Vision System FH/FHV/FZ5 Series User’s Manual (Z365)
Display mode • Modeless
• [BUSY ON]
Sets the display mode.
Modeless: Select this when using a display in which other
operations can be executed or other window parts
can be started (modeless display) while a speci-
fied Custom dialog is started.
BUSY ON: Select this when setting BUSY to ON while a
specified Custom dialog is started.
Macro Func. Sets this before and after starting the Setup window when call-
ing a macro subroutine.
Pre-Process [Blank] Specifies the subroutine name (including *) to execute before
displaying the Setup window using up to 32 characters.
Post-Process [Blank] Specifies the subroutine name (including *) to execute after
closing the Setup window using up to 32 characters.
Status Sets the status for the window part.
Enable [Blank] Specifies the variable to store the text display window status
from the variable assignment window.
However, only the scene variable or system variable can be
specified.
Refer to Assigning variables on page 5-61.
The variable value is:
0: Set the Custom dialog to disabled state.
Other than 0:Set the Custom dialog to enabled state.
Selected [Blank] Specifies the variable to store the text display window status
from the variable assignment window.
However, only the scene variable or system variable can be
specified.
Refer to Assigning variables on page 5-61.
The variable value is:
0: Set the Custom dialog to normal state.
Other than 0:Set the Custom dialog to selection state.
Front/Back [Blank] Specifies the variable to store the text display window status
from the variable assignment window.
However, only the scene variable or system variable can be
specified.
Refer to Assigning variables on page 5-61.
When the variable value is:
Positive: Move window to the front.
Negative: Move window to the back.
0: Do not move the window.
Control Sets when changing the status for the processing item setting
window display button using a macro.
Control ID 0 to 999 [0] The ID used to identify the operation target when using the
macro RaiseOptionEvent relationship to carry out operations.
Setting item
Setting value
[Factory default]
Description

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron fh-1 series and is the answer not in the manual?

Omron fh-1 series Specifications

General IconGeneral
BrandOmron
Modelfh-1 series
CategoryMachine Vision Systems
LanguageEnglish

Related product manuals