8 - 83
8 Setting Windows
Vision System FH/FHV/FZ5 Series User’s Manual (Z365)
8-4 Creating a Custom Dialog Box [Custom Dialog Functions]
8
8-4-2 Custom Dialog Tool
Combo Box Setting Region
If you change the measurement flow after you create a custom dialog box, change the target
unit number to match the edited measurement flow.
Parameter
Set value
[Factory default]
Description
Data Type • [Unit data (No.)]
• Unit data (ident)
• System data
• Scene variable
• System variable
Sets the unit specification method for targets for which to carry
out combo box settings.
The settings details vary depending on specification methods.
Target Unit No. 0 to Number of units in the
display target scene - 1 [0]
Sets when [Unit data (No.)] or [Unit data (ident)] is selected in
the "Data Type".
Use the unit number to specify the unit to be the target for the
combo box setting.
The units that are registered for the scene that is the target of
the normal dialog box will appear in the combo box.
Select the processing unit to set.
Unit label • [Unchecked]
• Checked
Sets when [Unit data (No.)] or [Unit data (ident)] is selected in
the "Data Type".
If using the unit label to specify the unit to be the target for the
combo box setting, select this and set the unit label.
Target data No. 0 to 9999999 [0] Sets when [Unit data (No.)] is selected in the "Data Type".
Specify the data to be the target for the combo box setting
using the data number.
Enter the data number for the unit that is specified by the target
unit number.
[Data reference]
button
Sets when [Unit data (No.)] is selected in the “Data Type”.
You can select the data number by directly entering it, or you
can enter it with the [Data reference] button.
Click the [Data reference] button to select the target data in the
[Data reference] dialog box.
Data ident Sets when [Unit data (ident)] is selected in the data type.
Use the unit data (identifier name) to specify the unit to be the
target for the combo box setting.
ident 0
ident 1
Sets when [System data] is selected in the “Data Type”.
Specify the system data to be the target for the combo box set-
ting using the identifier information 0 and identifier information 1.
(Refer to Vision System FH/FZ5 Series Macro Customize
Functions Programming Manual (Cat No. Z367-E1) system
data list.)
Scene variable Sets when [Scene variable] is selected in the “Data Type”.
Specify the scene variable to be the target for the radio button
setting using the scene variable name.
System variable Sets when [System variable] is selected in the “Data Type”.
Specify the system variable to be the target for the radio button
setting using the system variable name.
[Item setting]
button
Sets the item name and the data that corresponds to the item
name to display in the combo box. Make sure the number of
items and the number of data match.
• Items: Enter the name of the items to display in the combo box.
• Data No.: Enter the target data numbers that correspond to
each item in the combo box.