10   Advanced Usage
10 - 66
Vision System FH/FHV/FZ5 Series User’s Manual (Z365)
• Using the Flow
The motionless workpiece (or a saved image) is continuously measured until the calibration is 
completed.
This allows you to easily verify the operation of the calibration flow with the FH/FHV/FZ5-series 
Controller. Conventionally, you could not verity the calibration flow unless the Controller was inte-
grated into the system.
Refer to Machine Simulator of the Vision System FH/FHV/FZ5 Series Processing Item Function Ref-
erence Manual (Cat. No. Z341).
↓
Position measurement processing 
item
· · · Measure the position of the alignment marks or the position of 
a special feature of the workpiece from the image in Camera 1.
To output the position on the image, set [Calibration] on the 
[Output parameter] tab page to OFF.
Out of the general measurement processing items (Inspections 
and Measurements), you can use processing items with mea-
surement results that have an X and Y in the calculation 
strings.
↓
Vision Master Calibration processing 
item
· · · Set the machine setting processing item to reference, and then 
set the sampling.