Vision System FH/FHV/FZ5 Series User’s Manual (Z365)
11-1 Error Messages and Troubleshooting
11
Loading the startup Scene group failed. No
read location found. Try one of the following:
• When reading from an external storage
device, verify connection to the external
memory device and press OK button to do
load operation.
• To change the Startup scene group, select
Change startup scene.
• If there is no external storage device
attached, or no Startup scene group set,
in the Scene group saving destination set-
tings, select Save all scene group data in
the flash memory.
Here are some things to consider. Choose a remedy noting the
messages.
• No read location for the Scene group
• The external storage device containing the Scene group is cor-
rupted.
• The Scene group data is corrupted.
• You have selected a non-existing Scene group.
Moreover, when this error message is displayed even though
external storage has been connected, a recognition delay of exter-
nal storage happens at start-up of the Sensor Controller and load-
ing scene group data from the external storage may have failed.
Refer to 3-6-2 Device Information Storage Tool on page 3-35.
Warning range shall be set within the range
from judgement lower to upper limit.
Please redefine the upper and lower warning range limits such
that they are within the range between the lower and upper evalu-
ation limits.
Refer to Trend Monitor-Judgement Conditions (Trend Monitor) in
the Vision System FH/FHV/FZ5 Series Processing Item Function
Reference Manual (Cat. No. Z341).
The "Search" measurement result may be
"NG (Insufficient memory)" with the current
setting.
Insufficient memory may occur during measurement.
Reset the model parameters.
• [Search]
Refer to Search - Judgement is NG (Insufficient Memory) in the
Vision System FH/FHV/FZ5 Series Processing Item Function
Reference Manual (Cat. No. Z341).
• [Flexible search]
Refer to Flexible search - Judgement is NG (Insufficient Mem-
ory) in the Vision System FH/FHV/FZ5 Series Processing Item
Function Reference Manual (Cat. No. Z341).
• [Classification]
Refer to Classification - Judgement is NG (Insufficient Memory)
in the Vision System FH/FHV/FZ5 Series Processing Item Func-
tion Reference Manual (Cat. No. Z341).
Save operation failed due to insufficient
flash memory space in the Sensor Control-
ler. The current Scene group data in Sensor
Controller memory will be discarded after
system reboot.
• Increase the free memory space then re-try saving to the Sen-
sor Controller.
• Delete Scene, or Processing unit, or try adjusting the Measure-
ment region of the Processing unit, or the size of the registered
model.
• Set the Save destination for the Scene group data to be an
external storage device.
Refer to 7-5 Saving Scene Groups in External Storage [Scene
Group Saving Destination Settings] on page 7-10.
• Save the current Scene group data to external storage.
Refer to 9-3 Saving Setting Data to the Controller RAMDisk or
an External Storage Device on page 9-8.
The problem occurred in the system. This is displayed when the significant abnormality occurs in the
controller system. Please contact one of our branches or regional
offices.
The problem occurred in system date.
The system battery is insufficient.
Low battery (for the backup of date and time data) level.
The batteries need to be replaced.
Please return old batteries to one of our branches or regional
offices.
Failed to switch scene. Is a USBDisk set to the controller?
A USBDisk is needed to read scenes after scene group 1.
Error message Troubleshooting

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron fh-1 series and is the answer not in the manual?

Omron fh-1 series Specifications

General IconGeneral
BrandOmron
Modelfh-1 series
CategoryMachine Vision Systems
LanguageEnglish

Related product manuals