11 What to Do!
11 - 8
Vision System FH/FHV/FZ5 Series User’s Manual (Z365)
Although an error message such as the following, is not displayed, the ERROR signal and the ERR
indicator will turn ON.
The Logon to Network Server screen is dis-
played.
The connection was cut off based on the idling / session time set
on the network logging destination PC.
At the command prompt on the PC, enter the following:
net config server /autodisconnect:-1
Then disable the automatic disconnection setting.
Cause Troubleshooting
The STEP signal was input when the
READY signal was turned OFF.
• Input the STEP signal after the READY signal turns ON.
• Noise is superimposed onto the STEP signal. Keep PLC and FH
series / FZ5 series Sensor Controller away from the noise
source.
A non-existing parallel command was
entered.
• Please enter a correct parallel command.
The parallel scene group switch command
was executed when no USB memory was
installed.
(FZ5-L series / FZ5-600 series)
• Switch the scene group with the USB memory installed.
Error message Troubleshooting

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron fh-1 series and is the answer not in the manual?

Omron fh-1 series Specifications

General IconGeneral
BrandOmron
Modelfh-1 series
CategoryMachine Vision Systems
LanguageEnglish

Related product manuals