3 - 29
3 Basic Operations
Vision System FH/FHV/FZ5 Series User’s Manual (Z365)
3-3 Checking System Information
3
2 Click the [Close] button.
Memory state window will be closed.
With FH series and FZ5-800/1100/1200 series, when the amount of memory used in the Sen-
sor Controller exceeds a certain level, below warning message dialog will be displayed.
If this dialog is displayed, check the memory status and take the following measures to enlarge
the Virtual Available (MB).
Displayed item Description
The number of application process Differs depending on the Sensor Controller mode. Refer to 4-4 Set-
ting Operation Mode [Startup Settings] on page 4-12.
Standard = 1
Double Speed Multi-input = 2
Non-stop adjustment = 2
(Operation: Process 0, Adjustment: Process 1)
Multi line random trigger mode = Number of set lines
(Each line number corresponds to the process number).
Physical memory (the remaining capacity/
total capacity)
The remaining capacity and total capacity of the Physical memory
installed in the Sensor Controller.
Unit + Image Inclusive sum Total size of unit that is held by the scene group loaded to the Sen-
sor Controller and image data.
Virtual Available (MB) Amount of virtual memory usable.
2GB is applied to each application process.
This memory region can be temporary used by application process.
If you check the remaining capacity, you can confirm the operating
status. Users can not access to this memory.
Unit (MB) Total data size of the units held by Scene groups that are loaded to
the Sensor Controller.
Image (MB) Total data size of the image data held by Scene groups that are
loaded to the Sensor Controller.
Available application memory Item displayed with FZ5-L series and FZ5-600 series.
This is a memory region temporary used for the application. If you
check the remaining capacity, you can confirm the operating status.
Users can not access to this memory.
Available data memory Item displayed with FZ5-L series and FZ5-600 series.
Available data memory represents the memory capacity which can
be used for unit data and setting data for each unit out of the mem-
ory for Scene group data.
If the data memory used exceeds this, it becomes impossible to
add units in the flow and copy the scenes. Check the available data
memory and modify the scenes.
Status Countermeasures
Unit value it too large. Modify the Scenes and reduce the number of processing items.
Or split the Scene group.