Page #51 background image
Parker EME
Compax3 device description
192-120114 N5 C3I22T11 June 2008 51
Controller front plate
X20
X21
X22 X23
S24
X12 X13
X11
X3
LED3LED2
LED1
X4
X10
X3
Motor brake
X20
HEDA in (Option)
X4
24VDC
X21
HEDA out (Option)
X10
RS232/RS485 with jumper to the
programming interface
X22
Inputs Outputs (Option M10/12)
X11
Analog/Encoder
X23
Bus (Option)
connector type de-
pends on the bus
system!
X12
Inputs/Outputs
S24
bus settings
X13
Motor position feedback
LED1
Device status LEDs
LED2
HEDA LEDs
LED3
Bus LEDs
The internal device status LEDs are only connected to the external housing LEDs,
if the RS232 jumper at X10 is fitted to the control and the upper dummy cover is
fitted.
The RS232 programming interface under the upper dummy cover is only available
if the X10 jumper at the controller is fitted.
Always switch devices off before wiring them!
Dangerous voltages are still present until 5 minutes after switching
off the power supply!
Caution!
If the control voltage is missing and if the X10-X10 jumper is not fit-
ted (VBK17/01) on the control part, the availability of power voltage is
not displayed.
PE connection
The PE connection is made with 10mm
2
via a grounding screw at the bot-
tom of the device.
Attention hot surface!
Metal parts can heat up to a temperature of 90°C during operation.
Note on Compax3H:

Table of Contents

Other manuals for Parker Compax3 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker Compax3 Series and is the answer not in the manual?

Parker Compax3 Series Specifications

General IconGeneral
Enclosure RatingIP20
Control ModesSpeed, Torque, Position
Communication InterfacesCANopen, EtherCAT
Feedback OptionsIncremental Encoder, Resolver
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Cooling MethodForced Air, Natural Convection
Relative Humidity5 to 85 %, non-condensing
Operating Temperature0 to +45 °C (derating may apply above 40°C)