3
9929399 R01 - 2018-2019 RANGER XP/ CREW 900/1000 Service Manual
© Copyright Polaris Industries Inc.
3.129
15.Install the outer alternator cover and torque the
fasteners to specification.
TORQUE
Alternator Cover Fasteners:
48 lb-in (5.4 Nm)
COMPRESSOR REPLACEMENT
WARNING
In the event of a leak, wear safety goggles. Escaping
refrigerant can cause severe injuries to eyes. In contact
with a flame, R-134a refrigerant gives off a toxic gas.
1. Evacuate the refrigerant using an A/C recovery
system.
2. Remove the compressor drive belt. Refer to
“Compressor Drive Belt Replacement”page
3.127 procedure.
3. Disconnect the compressor clutch wire.
4. Remove the low pressure hose
q
from the
compressor.
5. Remove the high pressure hose
w
from the
compressor.
6. Cap and plug the compressor hoses and the fittings
with the proper A/C caps and plugs.
7. Remove the compressor mounting fasteners.
8. To install, reverse the procedure.
TORQUE
Compressor Low Pressure Hose:
25 lb-ft (34 Nm)
Compressor High Pressure Hose:
18 lb-ft (24 Nm)
Compressor Mounting Fasteners:
37 lb-ft (50 Nm)
9. Recharge the A/C system.