Remote Commands Reference
R&S
®
RTC1000
200User Manual 1335.7352.02 ─ 02
TRIGger:A:TYPE <Type>
Sets the trigger type.
Parameters:
<Type> EDGE | WIDTh | TV | LOGic | BUS
EDGE:
Edge trigger
WIDTh:
Pulse trigger
TV:
Video trigger
LOGic:
Logic trigger
BUS:
BUS trigger requires that at least one serial protocol option is
installed.
*RST:
EDGE
TRIGger:A:HOLDoff:MODE <HoldOffMode>
Enables or disables the holdoff time.
Parameters:
<HoldOffMode> TIME | OFF
*RST: Off
TRIGger:A:HOLDoff:TIME <HoldOffTime>
Defines the holdoff time. The next trigger occurs only after the holdoff time has passed.
Parameters:
<HoldOffTime> Range: 5.00000E-08 to 1.00000E+01
Default unit: s
TRIGger:OUT:MODE <OutputMode>
Sets the trigger output mode. Defines the trigger output mode wether and when a trig-
ger out pulse is generated.