SERVICE CALL CONDITIONS
B132/B200 4-48 SM
Duplex jogger motor error 1
SC515 C
When the jogger fence moves to
the home position, the jogger
fence HP sensor does not switch
on even after the jogger motor
has moved the jogger fence
153.5 mm.
Rear fence motor defective or poor
connection
Paper or other obstacle interfering with
operation of the sensors or motor
Return sensor or HP sensor defective or
dirty
Duplex jogger motor error 2
SC516 B
When the jogger fence moves
from the home position, the
jogger fence HP sensor does not
turn off even if the jogger motor
has moved the jogger fence
153.5 mm.
Paper or other obstacle has jammed
mechanism
HP sensor connector disconnected or
defective
HP sensor defective
Fusing/Exit Motor error
SC520 A
The Fusing/Exit Motor LOCK
signal is not detected for the
duration of one second after the
motor START signal is sent.
Fusing/Exit Motor connecter is not
connected correctly.
Fusing/Exit Motor torque is too high or
too low.
Fusing/Exit Motor is defective.
Fan error 1: fusing fan motor
SC530 D
The BCU does not receive the
lock signal 5 seconds after the
fusing unit fan switches on.
Fusing unit cooling fan disconnected,
defective
BCU defective
Fan error 2: fusing fan motor
SC531 D
The lock signal remained HIGH for 5 sec.
while the fan at the front of the fusing unit
near the heat dissipation fins was operating.
Motor overload due to
obstacle interfering with
operation of the fan
Fan harness loose,
disconnected, defective
Fan defective
Fan error 3: PCB box fan
SC532 D
The lock signal remained HIGH for 5 sec.
while the fan that cools the printed circuit
boards was operating.
Motor overload due to
obstacle interfering with
operation of the fan
Fan harness loose,
disconnected, defective
Fan defective
Fan error 4: fusing exhaust fan
SC533 D
The lock signal remained HIGH for 5 sec.
while the fan that draws air out of the fusing
unit was operating.
Motor overload due to
obstacle interfering with
operation of the fan
Fan harness loose,
disconnected, defective
Fan defective
Rev. 07/2005