SERVICE CALL CONDITIONS
SM 4-49 B132/B200
Fan error 5: duplex exhaust fan
SC534 D
The lock signal remained HIGH for 5 sec.
while the fan that draws air out of the duplex
unit was operating.
• Motor overload due to
obstacle interfering with
operation of the fan
• Fan harness loose,
disconnected, defective
• Fan defective
Temperature/Humidity control abnormal
SC535 C
The output of the
temperature/humidity sensor
reaches the upper or lower limit,
even after the Peltier unit has
been ON for 3 hours.
• Peltier Cooling Fan Motor is defective.
Heating roller thermistor 1 error 1: Poor connection
SC541 A
The temperature measured by
the heating roller thermistor
does not reach 130°C after 10
tries and 65 sec. have elapsed.
• Heating roller thermistor harness
connection loose, disconnected,
defective
• Defective heating roller thermistor
Heating roller thermistor 1 error 2: No warmup
SC542 A
After the main switch is turned
on or the cover is closed, the
heating roller temperature does
not reach the ready temperature
within 2 sec. after the heater
switches on.
-or-
If the roller was below 45°C, the
heating roller did not reach the
ready temperature 2 sec. after
reaching 45°C.
Note: Thermistor 2 stops
monitoring the temperature once
Thermistor 1 detects ready
temperature.
• Thermistor is bent, installed incorrectly
• Defective heating roller thermistor
• Heating roller fusing lamp broken
Do SP5810 to cancel the SC fusing code.
Heating roller thermistor 1 error 3: Software - High temperature
SC543 A
The thermistor detected a
temperature over 230°C times
within 1 sec.
• TRIAC short, IOB defective
• BICU defective
• Fusing temperature out of control
Do SP5810 to cancel the SC fusing code.
Heating roller thermistor 1 error 4: Hardware - High temperature
SC544 A
The thermistor detected a
temperature over 260°C..
• TRIAC short
• IOB defective
• BICU defective
• Fusing temperature control is erratic
Do SP5810 to cancel the SC fusing code.
⇒