SERVICE PROGRAM TABLES
SM 5-39 B132/B200
Service Tables
030 CMY:LowMin. No information is available at this time.
[0~50/0.1V]
031 CMY:MidMin. No information is available at this time.
[0~50/0.1V]
032 Base MaxDiff No information is available at this time.
[0~50/0.1V]
033 Patch Mini Gap No information is available at this time.
[0~50/0.1V]
034 Light Target Adj
Sets the target value for the intensity of the MUSIC sensor
lights.
[0~50/0.1V]
035 MY Light Max
Sets the maximum value for the intensity of the MUSIC
sensor lights.
[0~255/0.1V]
036 Add Upper Limit
037 Add Lower Limit
038 LaserX:FrontXf
039 LaserX:CenterXc
040 LaserX: RearXr
041 LaserX: TempCoeff
No information is available at this time.
2154 2-Point Target 2-Point Interval Target Setting
These 2-point target settings done at the factory affect the characteristics of the
lenses. These target values must be entered when when the laser unit is replaced.
The correct settings are printed below the first barcode on one A5 sheet of paper
provided with the replacement laser unit.
001 K [60700~63230/61984/1]
002 M
003 C
004 Y
2155 2-Point Int Set 2-Point Interval Target Setting DFU
These SPs adjust the difference in the position of color registration for MUSIC in
the main scan direction, using K (black) as the reference point.
Do SP2109 002 and print Pattern 1 on A3 size paper. Examine the pattern with a
scaled lupe. For every 43.2µm adjust the setting in the left or right direction. A 1
step correction corrects 50µm. For more, please refer to Section "3.
Replacement and Adjustment".
001
M Main Scan
002
C Main Scan
003
Y Main Scan
[-5~+5/1 (43.2µm)