SERVICE PROGRAM TABLES
SM 5-101 B132/B200
Service Tables
4609 White Plate:R Standard White Plate Adjustment: Red DFU
4610 White Plate:G Standard White Plate Adjustment: Green DFU
4611 White Plate:B Standard White Plate Adjustmetn: Blue DFU
This SP codes display the reference voltages stored in NVRAM at the factory for
Red, Green, and Blue before the machine was shipped. The SBU acquires these
settings every time the machine is switched on.
[-256~+255/1]
4628 Gain Adj Range:R Gain Adjustment Range: R DFU
4629 Gain Adj Range:G Gain Adjustment Range: G DFU
4630 Gain Adj Range:B Gain Adjustment Range: B DFU
When switched on, these SP display the current range for the gain of RED, GREEN,
and BLUE in the ASCI on the SBU after white level adjustment every time the
machine is switched on.
001 Color
002 B/W
[0~1/1]
4631 Gain Adj Range:R Gain Adjustment Range: R DFU
When switched on, this SP displays the current range for the E (EVEN) or O (ODD)
in the ASCI on the SBU after white level adjustment every time the machine is
switched on.
001 RE
002 RO
[0~1/1]
4632 Gain Adj Range:G Gain Adjustment Range: G DFU
When switched on, this SP displays the current range for E (EVEN) or O (ODD)
gain of GREEN or B/W in the ASCI on the SBU after white level adjustment every
time the machine is switched on.
001 Color:GE
002 Color:GO
005 B/W:GE
006 B/W:GO
[0~1023/1]
4633 Gain Adj Range:B Gain Adjustment Range: B DFU
When switched on, this SP displays the current range for E (EVEN) or O (ODD) gain
of BLUE in the ASCI on the SBU after white level adjustment every time the machine
is switched on.
001 BE
002 BO
4641 White Lvl Loop White Level Loops DFU
Displays the number of loops done color correction for AGC (Automatic Gain
Correction) during white level adjustment.
001 Color
002 B/W
[0~1023/1]