SERVICE PROGRAM TABLES
B132/B200 5-102 SM
4646 Scan Auto Error Error Flag for Automatic Adjustment: Scanning DFU
This SP sets the error flag to display as the SBU is updated automatically when the
machine is switched on.
001 Gain
002 K Level
[0x00~0xFFFF]
b7 GAIN_ERR_BO
b6 GAIN_ERR_BE
b5 GAIN_ERR_BK_GO
b4 GAIN_ERR_BK_GE
b3 GAIN_ERR_GO
b2 GAIN_ERR_GE
b1 GAIN_ERR_RO
b0 GAIN_ERR_RE
4647 HW Error Flag Hardware Error Flag Adjustment: Scanning DFU
This SP sets the error flag to confirm machine ON processing when the machine is
switched on.
[0x00~0x3F]
4680 Fact Gain Adj:R Factory Gain Adjustment at Factory: Red DFU
When switched on, this SP displays the setting done at the factory for RED O (ODD)
and E (EVEN) gain in the ASCI on the SBU after white level adjustment every time
the machine is switched on.
001 RE
002 RO
[0~1023/1]
4681 Fact Gain Adj:G Factory Gain Adjustment at Factory: Green DFU
When switched on, this SP displays the setting done at the factory for GREEN and
black-and-white O (ODD) and E (EVEN) gain in the ASCI on the SBU after white
level adjustment every time the machine is switched on.
001 Color:GE
002 Color:GO
005 B/W:GE
006 B/W:GO
[0~1023/1]
4682 Fact Gain Adj:B Factory Gain Adjustment at Factory: Blue DFU
When switched on, this SP displays the setting done at the factory for BLUE O
(ODD) and E (EVEN) gain in the ASCI on the SBU after white level adjustment every
time the machine is switched on.
001 BE
002 BO
[0~1023/1]
4690 White Lvl Peak:R White Level Peak: Red Scan Data DFU
When switched on, these SP codes display E (EVEN) or O (ODD) for the white level
peak RED data after white level detection (AGC) after the machine is switched on.
001 RE
002 RO
[0~255/1]