NCU Parameters
SM 153 D629
Fax Option
Type 5002
(D629)
Address Function Unit Remarks
6805E4
Bit 0 OHS (on hook speed)
0: OHS=0
1: OHS=1
Bit 1 SQ (spark quench)
0: SQ=00
1: SQ=11
Bit 2 RZ (call signal Impedance)
0: RZ=0 (high)
1: RZ=1 (low)
Bit 3 RT (call signal detection level)
0: RT=0 (low)
1: RT=1 (high)
Bit 4 ILIM (DC limitation)
0: ILIM=0 (CTR 21)
1: ILIM=1 (other than CTR 21)
Bit 5 FILTER
0: FILTER=0 (around 5Hz)
1: FILTER=1 (around 200Hz)
Bits 6 to 7 Calibration in off hook state
Bit 6:0, Bit 7: 0 = off hook to ACAL:128 ms, off hook to MCAL: 1000 ms
Bit 6:1, Bit 7: 0 = off hook to ACAL:128 ms, off hook to MCAL: 500 ms
Bit 6:0, Bit 7: 1 = off hook to ACAL:128 ms (no MCAL)
Bit 6:1, Bit 7: 1 = off hook to ACAL:8 ms (no MCAL)
6805E5
Bits 0 to 6 Not used
Bits 7 Energy saving for DSP, COMBLK, SiDAA
0: Does not save energy
1: Saves energy