Tables
1106 Fusing Temperature Display
001 Roller Center Displays the temperature of the fusing
unit.
[-20 to 250 / 0 / 1 deg]
002 Roller Ends
003 Machine Inside at Power On Displays the temperature inside the
machine.
[-20 to 250 / 0 / 1 deg]
004 Machine Inside
1801*
MotorSpeedAdjust
Adjusts the speeds of each motor. Each step decreases or increases motor
speed in 0.05% increments
Regist: Registration motor, Feed: Feed motor,
Duplex: Duplex/By-pass motor, Inverter: Duplex inverter motor,
Exit: Paper exit motor, Bridge: Bridge unit drive motor,
OpcMot: Drum motor, TransferMot: Transfer/Development Motor,
FusingMot: Fusing motor,
DevPuddleMot: Development Paddle motor
001 Regist: 90: Thick 2
[-2 to 2 / 0.4 / 0.05 %]
002 Regist: 154: Thick 1
003 Regist: 180: Plain
004 Regist: 230: Plain
005 Feed: 90: Thick 2
[-2 to 2 / -0.4 / 0.05 %]
006 Feed: 154: Thick 1
007 Feed: 180: Plain
[-2 to 2 / -1 / 0.05 %]
008 Feed: 230: Plain
009 Duplex_CW: 90: Thick 2
[-4 to 4 / 0.4 / 0.1 %]
010 Duplex_CW: 154: Thick 1
011 Duplex_CW: 180: Plain [-4 to 4 / -2.3 / 0.1 %]