Tables
4631
Digital Gain Adjust
Displays the gain value of the amplifiers on the controller for RE or RO.
001 Latest: RE Color [0 to 1023 / 0 / 1 digit]
002 Latest RO Color [0 to 1023 / 0 / 1 digit]
4632
Digital Gain Adjust
Displays the gain value of the amplifiers on the controller for GE or GO.
001 Latest: GE Color [0 to 1023 / 0 / 1 digit]
002 Latest: GO Color [0 to 1023 / 0 / 1 digit]
4633
Digital Gain Adjust
Displays the gain value of the amplifiers on the controller for BE or BO.
001 Latest: BE Color [0 to 1023 / 0 / 1 digit]
002 Latest: BO Color [0 to 1023 / 0 / 1 digit]
4645
Scan Adjust Error
Displays the error value of the white level or black level adjustment.
001 White level [0 to 65535 / 0 / 1 digit]
002 Black level [0 to 65535 / 0 / 1 digit]
4647
Scanner Hard Error
Displays the result of the SBU connection check.
Power-ON
[0 to 35535 / 0 / 1 ]
0: OK, 1: SBU connection check failure
If the SBU connection check fails, SC144-001, -002 or
-003 occurs.