Tables
011
Port 80 Enable
Enables/disables access via port 80 to the SOAP method.
[0 or 1 / 0 / – ]
0: Disabled, 1: Enabled
012
@Remote Communication Permission
[0 to 2 / 1 / 1 ]
0: Not permitted
1: Permitted
2: Partially limited
013
RFU (Remote Firmware Update) Timing
Selects the RFU timing.
[0 or 1 / 1 / – ]
0: RFU is executed whenever update request is received.
1: RFU is executed only when the machine is in the sleep mode.
014
RCG Error Cause
[0 or 1 / 0 / – ]
0: Normal
1: Fails to reflect the client/server certificate settings by network failure to
reboot. Transition to 0 on restarting the machine.
021
RCG–C Registed
This SP displays the Embedded RC Gate installation end flag.
0: Installation not completed
1: Installation completed
023
Connect Type (N/M)
This SP displays and selects the Embedded RC Gate connection method.
[0 or 1 / 0 / 1 /step
0: Internet connection
1: Dial-up connection