Service Call Conditions
D129/D130 6-26 SM
651 C
Incorrect dial up connection
-001: Program parameter error
-002: Program execution error
An unexpected error occurs when the modem (Embedded RCG-M) tries to
call the center with a dial up connection.
Caused by a software bug
652 D
ID2 mismatching
ID2 for @Remote certification is mismatching between the controller board
and NVRAM.
Used controller board installed
Used NVRAM installed
An unexpected error occurs when the modem (Embedded RCG-M) tries to
call the center with a dial up connection.
1. Install the correct controller board or new controller board.
2. Install the correct NVRAM or new NVRAM.
653 D
ID2 error
ID2 stored in the NVRAM is incorrect.
Used NVRAM installed
An unexpected error occurs when the modem (Embedded RCG-M) tries to
call the center with a dial up connection.
Clear the ID2 in the NVRAM, and then input a correct ID2.