Service Call Conditions
SM 6-49 D129/D130
Trouble-
shooting
833 C Self-diagnostic error 8: Engine I/F ASIC
[0F30]
[0F31]
ASIC (Mandolin) for system control could not be detected. After the PCI
configuration, the device ID for the ASIC could not be checked.
Replace the IPU.
[0F41]
ASIC (Mandolin) for system control could not be detected. After the PCI
configuration, the device ID for the ASIC could not be checked.
Replace the IPU.
[50B1]
Could not initialize or read the bus connection.
Check for loose connections at the mother board.
Replace the IPU.
[50B2]
Value of the SSCG register is incorrect.
Check for loose connections at the mother board.
Replace the IPU.