Service Call Conditions
D129/D130 6-50 SM
835 C Self-diagnostic error: Centronic device
[1102]
Loopback connector is connected but check results in an error.
IEEE1284 connector error
Centronic loopback connector defective
Replace the controller board.
[110C]
Loopback connector is connected but check results in an error.
ASIC device error
IEEE1284 connector error
Centronic loopback connector defective
Replace the controller board.
[1120]
Centronic loopback connector is not connected for detailed self-diagnostic
test.
Centronic loopback connector not connected correctly
Centronic loopback connector defective
ASIC device defective
Replace the controller board.
838 B Self-diagnostic Error: Clock Generator
[2701]
A verify error occurred when setting data was read from the clock generator
via the I2C bus.
Defective clock generator
Defective I2C bus
Defective I2C port on the CPU
Replace the controller board.