Service Call Conditions
D129/D130 6-68 SM
Procedure 4
If "Procedure 3" is not the solution for the problem, replace the HDD.
990 D
Software error 1
The software performs an unexpected function and the program cannot
continue.
Software defective, re-boot
991 C
Software error 2
The software performs an unexpected function. However, unlike SC990,
recovery processing allows the program to continue.
Software defective, re-boot
In order to get more details about SC990 and SC991:
1) Execute SP7403 or print an SMC Report (SP5990) to read the history of the 10 most recent
logged errors.
2) If you press the zero key on the operation panel with the SP selection menu displayed, you
will see detailed information about the recently logged SC990 or SC991, including the software
file name, line number, and so on.
1) is the recommended method, because another SC could write over the information
for the previous SC.
992 D
Undefined error
Defective software program
An error undetectable by any other SC code occurred
994 C
Application Item Error
The number of executed application items on the operation panel reach
the maximum limit for the operation panel structure.
Too much executed application items