System SP Tables-2
SM Appendix 3-41 D129/D130
Appendix:
Service
Program
Mode Tables
2975*
Near End Setting
Detection Time [0 to 2000 / 0 / 10 sec ]
Sets a time for toner supply motor rotation for issuing the toner near end
warning on the operation panel. The time may need to be shorter for
customers who run especially large print jobs (working at night, for example)
to ensure earlier warning of the toner near end condition so toner out does
not interrupt a long job.
2976*
Bottle Motor Time
Displays the total ON time of the toner supply motor, calculated from when
the toner bottle was replaced. Use this to check that the toner end count
(SP2975) is working properly.
When SP2975 is set to any value other than "0", this value is displayed
when it matches the setting of SP2975. When SP2975 is set to "0", SP2976
is disabled. SP2976 is automatically set to zero by toner end recovery.)