System SP Table-3
D129/D130 3-44 SM Appendix
3902* New PCU Detection (Not used)
001
On/OFF Setting
[0 to 1 / 0 / 1]
0: On, 1: Off
Turns on or off the new unit detection for the transfer belt unit and fusing
unit.
3905*
Hot Roller Stripper Cleaning
"Cleaning A": 15 sec. off/on cycle for the fusing motor.
"Cleaning B": Off (45 sec.) and On (15 sec.) cycle for the fusing motor.
001
1st Cleaning: Interval
Sets the threshold for the 1st cleaning mode.
"Cleaning A" is done once.
[0 to 5 / 5 / 1 sheets]
002
1st Cleaning: Mode Setting
Sets the number of additional execution times of the 1st cleaning mode.
[0 to 5 / 0 / 1 times]
003
2nd Cleaning: Interval
Sets the threshold for the 2nd cleaning mode.
"Cleaning A" is done twice.
[6 to 49 / 30 / 1 sheets]
004
2nd Cleaning: Mode Setting
Sets the number of additional execution times of the 2nd cleaning mode.
[0 to 5 / 0 / 1 times]
005
3rd Cleaning: Interval
Sets the threshold for the 3rd cleaning mode.
"Cleaning A" is done twice and "Cleaning B" is done "N" times.
"N" is specified with SP3905-006.
[50 to 999 / 100 / 1 sheets]