Main SP Tables-1
D158/D159/D160/D161/D170 3-8 SM Appendix
1106
[Fusing Temperature Display] Fusing Temperature Display (Heating or
Pressure)
Displays the current temperature of the heating and pressure rollers.
001 Roller Center ENG
[-20 to 250 / 0 / 1 deg / step]
002
Roller Ends ENG
[-20 to 250 / 0 / 1 deg / step]
The heating roller has two lamps. One heats the center of the heating roller
and the other heats both ends of the heating roller.
003
In The Machine at Power
On
(Mac at Power On)
ENG
[-20 to 250 / 0 / 1 deg / step]
The pressure roller has two lamps. One heats the center of the heating roller
and the other heats both ends of the heating roller.
1107
[Fusing Soft Start] (D160/D161/D170)
-
003
Softstop 100V *ENG
[0 to 1 / 0 / 1 / step]
004
Softstop 200V *ENG
[0 to 1 / 0 / 1 / step]
1108
[Fusing Soft Start Setting] (D158/D159)
[Fusing Soft St Set] (D160/D161/D170)
Sets the target temperature for immediately after reload temperature has
been achieved or paper has been fed.
001
Warming-Up *ENG
[100 to 2000 / 1000 / 100 msec / step]
002
Print *ENG
[100 to 2000 / 1000 / 100 msec / step]
003
Wait *ENG
[100 to 2000 / 1000 / 100 msec / step]
004
Print Start *ENG
[100 to 2000 / 1000 / 100 msec / step]
005
Print Start Time *ENG
[0 to 999 / 5 / 1 sec / step]

Table of Contents