Main SP Tables-1
SM Appendix 3-9 D158/D159/D160/D161/D170
Service
Program
Mode Tables
1110
[Fan Control Timer] (D160/D161/D170)
Specifies the fan control time. The fan motor keeps its operating speed for the
specified time before changing the speed or stopping. The fan control timer
prevents the exhaust fan from suddenly stopping. This function protects the
copier from overheating.
001
Fan Control Timer *ENG
[30 to 60 / 30 / 100 msec / step]
1112
[Image Process Temp.]
These SPs are used for the fusing temperature control for variable job
images. This control saves the power consumption when the machine copies
or prints a job text image in black and white mode.
001
Correction Temp. : Normal:
Level1
*ENG
[-25 to 10 / 0 / 1 deg / step]
002
Correction Temp. : Normal:
Level2
*ENG
[-25 to 10 / -5 / 1 deg / step]
1124
[CPM Down Setting] (D160/D161/D170)
Sets the temperature differential used to calculate CPM down for low and high
temperatures. Also, sets the interval for temperature checks for CPM down.
001
Low:Down Temp.
(Low:Down Tp)
*ENG
[-50 to 0 / -25 / 1 deg / step]
002
Low:Up Temp.
(Low:Up Tp)
*ENG
[-50 to 0 / -5 / 1 deg / step]
003
Low :1st CPM *ENG
[10 to 100 / 75 / 5 % / step]
004
Low :2nd CPM *ENG
[10 to 100 / 65 / 5 % / step]
005
Low :3rd CPM *ENG
[10 to 100 / 40 / 5 % / step]
006
High:1st CPM :Plain1
(High:1st CPM:20)
*ENG
[10 to 100 /
D158/D160/D161/D170:60,
D159:50 / 5%/step]