Main SP Tables-2
D158/D159/D160/D161/D170 3-28 SM Appendix
004
Deterioration Coverage Sum
Threshold
*ENG
[0 to 30000 / 18700 / 1cm^2 / step]
Controls special mode in low image when this value is reached more than
SP2-401-003.
005
Charge Bias Correction *ENG
[-300 to 0 / -50 / 10 vol / step]
Adds this value to SP2-001-001 (the controlling value of the normal charging
voltage) when controlling the toner adhesion amount control.
006
Development Bias Correction *ENG
[-300 to 0 / -50 / 10 vol / step]
Adds this value to SP2-201-001 (the controlling value of the normal
development voltage) when controlling the toner adhesion amount control.
2401
[Separation Voltage] (D160/D161/D170)
-
001 1side/Lead Edge *ENG
[-4000 to 0 / 0 / 10 V / step]
002 1side/Image Area *ENG
[-4000 to 0 / 0 / 10 V / step]
003 2side/Lead Edge *ENG
[-4000 to 0 / 0 / 10 V / step]
004 2side/Image Area *ENG
[-4000 to 0 / 0 / 10 V / step]
005 Switching Timing *ENG
[-20 to 20 / 15 / 1 mm / step]
2801
[Developer Initialization] (D158/D159)
[Devlpr Initialize] (D160/D161/D170)
001
Standard Speed
(Devlpr Initialize)
ENG
[- / - / -]
[Execute]
Executes developer initialization when new PCU is replaced.

Table of Contents