Service
Program
Mode Tables
2933
[ID Sensor Control Correction] (D158/D159)
[ID Sensor Adj] (D160/D161/D170)
Adjusts the correction value for P sensor. This SP is design use only and do
not change.
001 - *ENG
[0.0 to 3.0 / 1.0 / 0.1 / step]
2934
[ID Sensor PWM Setting] (D158/D159)
[ID Error Analysis] (D160/D161/D170)
001
Dilay
(PWM)
*ENG
[0 to 1023 / 200 / 1 / step]
Displays ID Sensor PWM value.
003
Upper Limit Correction *ENG
[0 to 1023 / 100 / 1 / step]
Upper limit value of ID sensor PMW.
2935
[ID Sensor Initialization] (D158/D159)
This SP clears PWM value and executes Vsg adjustment again, then resets
PWM value.
001 - ENG
[0 or 1 / 0 / 1 / step]
2936
[ID Sensor Detection Interval] (D158/D159)
[ID Sensor Detection] (D160/D161/D170)
Counts every page printed. If this counter reached the number set in
SP9-995-002, interrupt the print job and do the process set in SP2-995-003.
001 Counter *ENG
[0 to 999 / 0 / 1 page / step]