Main SP Tables-2
D158/D159/D160/D161/D170 3-34 SM Appendix
2929
[Vref Adjustment] (D158/D159)
[Vtref Limits] (D160/D161/D170)
Adjust the upper or lower Vref limit.
001
Upper Limit
(Upper)
*ENG
[0.50 to 3.50 / D158/D159:2.80,
D160/D161/D170:2.45 / 0.05 vol /
step]
002
Lower Limit
(Lower)
*ENG
[0.50 to 3.50 / D158/D159:1.4,
D160/D161/D170:1.25 / 0.05 vol /
step]
2930
[TD Sensor Manual Setting] (D158/D159)
Manually enters Vtref value. SP2-926-001 will be disabled when this SP is set.
001 - *ENG
[0.00 to 5.00 / 0.00 / 0.05 vol / step]
2931
[TD (V/ wt%) Setting]
Sets the toner supply ease.
001 [V/ wt%] *ENG
[0.01to 1.50 / 0.40 / 0.01 / step]
2932
[Toner Density Control Level] (D158/D159)
[Toner Density Adj] (D160/D161/D170)
Enables when SP2-921-001 (the toner supply mode) is set to "1: Normal2".
0:Normal
1:Dark
2:Light
3:Darker
4:Lighter
001 Level Select *ENG
[0 to 4 / 0 / 1 / step]