Service
Program
Mode Tables
2926
[Standard Vt] DFU
Sets reference value of T sensor control to control toner density.
This SP clears SP2-224-001: Copies After Toner Near End
001 - *ENG
[0.00 to 5.00 / D158/D159:2.50,
D160/D161/D170:2.40 / 0.05 vol /
step]
2927
[ID Sensor Control Function Select] (D158/D159)
[ID Sensor Control] (D160/D161/D170)
Determines whether the ID sensor signal is referenced or not for the toner
density control. Keep the default value in usual operations.
001
0: Off , 1: On
(ID Sensor Control)
ENG
[0 or 1 / 1 / 1 / step]
0: Correction Off
1: Correction On
2928
[Toner End Clear]
Clears the following messages and counters without supplying the toner:
Toner near end message
Toner end message
Toner near end counter
Toner end counter
is abnormally insufficient, the drum may attract the toner carrier to its surface.
The toner carrier might damage the drum surface.
001
0: Off , 1: On
(Toner End Clear)
ENG
[0 or 1 / 0 / 1 / step]