Main SP Tables-2
D158/D159/D160/D161/D170 3-32 SM Appendix
2922
[Toner Supply Time [sec]] (D158/D159)
[Toner Supply Time] (D160/D161/D170)
Adjusts the toner supply time. The toner supply motor remains on for the
specified time. To validate this setting, select "0" in SP2-921-001. Specify a
greater value if the
solid black image areas.
001 - *ENG
[0.1 to 5.0 / 0.4 / 0.1 / step]
2923
[Toner Recovery Time] (D158/D159)
[Toner Recovery] (D160/D161/D170)
Sets the toner recovery time.
001 - *ENG
D158/D159:
[1 to 60 / 30 / 1 sec / step]
D160/D161/D170:
[3 to 60 / 30 / 1 sec / step]
2925
[Toner Supply Ratio] (D158/D159)
[Toner Supply Rate] (D160/D161/D170)
0: x1
1: x2
2: x4
3: x8
4: x12
5: x16
6: Continuation
7: Not Supply
001
Ratio Select
(Toner Supply Rate)
*ENG
[0 to 7 / 0 / 1 / step]