Main SP Tables-4
SM Appendix 3-73 D158/D159/D160/D161/D170
Appendix:
Service
Program
Mode Tables
4903
[Filter Setting] (D158/D159 )
This SP outputs the final data read at the end of ACC execution.
A zero is returned if there was an error reading the data.
001
Ind Dot Erase: Text *ENG
Photo C Patch Level 1 (8-bit)
[0 to 7 / 0 / 1 / step]
002
Ind Dot Erase: Generation
Copy
*ENG
Photo M Patch Level 1 (8-bit)
[0 to 7 / 0 / 1 / step]
4903
[ADS Level] (D160/D161/D170)
Adjusts the ADS level.
001 ADS Level *ENG
[0 to 255 / 252 / 1 / step]
4904
[ADS Lower Limit] (D160/D161/D170)
Adjusts the ADS lower limit.
001 ADS Lower Limit *ENG
[0 to 255 / 80 / 1 / step]
4905
[Select Gradation Level] (D158/D159 )
-
001 Select Gradation Level *ENG
[0 to 255 / 0 / 1 / step]
4905
[ADS Area Select] (D160/D161/D170)
Checks the whole area (0 = All) or the specific areas (1 = One) to adjust the
ADS level. The specific areas are as follows:
ADF: 15 to 90 mm from the left edge
Platen Cover: 15 to 90 mm from the left edge
001 Select Gradation Level *ENG
[0 or 1 / 0 / 1 / step]