Main SP Tables-5
D158/D159/D160/D161/D170 3-110 SM Appendix
5501
[PM Alarm] (D158/159)
[PM Alarm Interval] (D160/D161/D170)
001
PM Alarm Level
(Printout)
*CTL
[0 to 9999 / 0 / 1/step]
0: Alarm off
1 to 9999: Alarm goes off when
(1 to 9999) x 1000 > PM counter
002
Original Count Alarm
(D158/159)
*CTL
[0 or 1 / 0 / 1/step]
0: No alarm sounds
1: Alarm sounds after the number of
originals passing through the ARDF >
10,000
5504 [Jam Alarm] (D158/159)
001
Jam Alarm *CTL
[0 to 3 / 3 / 1/step]
0: Zero (Off)
1: Low (2.5K jams)
2: Medium (3K jams)
3: High (6K jams)
Sets the alarm to sound for the specified jam level (document miss feeds are
not included).
5505
[Error Alarm] (D158/159)
Sets the error alarm level.
The error alarm counter counts "1" when any SC is detected. However, the
error alarm counter decreases by "1" when an SC is not detected during a set
number of copied sheets (for example, default 2000 sheets).
The error alarm occurs when the SC error alarm counter reaches "5".
001 Error Alarm *CTL
[0 to 255 / 20 / 1hundred/step]