Bit Switches - 3
D702 90 SM
Communication Switch 17 (SP No. 1-104-024)
No Function Comments
0
SEP reception
0: Disabled
1: Enabled
0: Polling transmission to another maker's
machine using the SEP (Selective Polling) signal
is disabled.
1
SUB reception
0: Disabled
1: Enabled
0: Confidential reception to another maker's
machine using the SUB (Sub-address) signal is
disabled.
2
PWD reception
0: Disabled
1: Enabled
0: Disables features that require PWD
(Password) signal reception.
3-4 Not used Do not change the settings.
5
PSTN dial-in routing setting
0: OFF
1: ON
1: The machine sets multiple PSTN dial-in
numbers in the PSTN dial-in line and transfers
received data from each PSTN dial-in number to
each address.
6 Not used Do not change the settings.
7
Action when there is no box
with an F-code that matches
the received SUB code
0: Disconnect the line
1: Receive the message
(using normal reception mode)
Change this setting when the customer requires.
Communication Switch 18 (SP No. 1-104-025)
No Function Comments
5
IP-Fax dial-in routing selection
0: Off
1: On
1: Transfers received data to each IP-Fax dial-in
number.
IP-Fax dial-in number is a 4-digit number.
6
PSTN 2 dial-in routing
0: Off
1: On
Enables or disables dial-in routing for the PSTN
2 connection.
7
PSTN 3 dial-in routing
0: Off
1: On
Enables or disables dial-in routing for the PSTN
3 connection.