TYPE M1
(D702)
Communication Switch 10 (SP No. 1-104-017)
No Function Comments
0-7
Memory transmission:
Maximum number of dialing
attempts to the same
destination
01 – FE (Hex) times
Communication Switch 12 (SP No. 1-104-019)
No Function Comments
0-7
Memory transmission: Interval
between dialing attempts to
the same destination
01 – FF (Hex) minutes
Communication Switch 14 (SP No. 1-104-021)
No Function Comments
0
Inch-to-mm conversion during
transmission
0: Disabled, 1: Enabled
0: In immediate transmission, data
scanned in inch format are transmitted
without conversion.
In memory transmission, data stored in
the SAF memory in mm format are
transmitted without conversion.
Note: When storing the scanned data
into SAF memory, the fax unit always
converts the data into mm format.
1: The machine converts the scanned
data or stored data in the SAF memory
to the format which was specified in the
set-up protocol (DIS/NSF) before
transmission.
6-7
Available unit of resolution in which fax
messages are received
For the best performance, do not
change the factory settings.
The setting determined by these bits is
informed to the transmitting terminal in
the pre-message protocol exchange (in
the DIS/NSF frames).
Bit 7 Bit 6 Unit
0 0 mm
0 1 inch
1 0 mm and inch
1 1 Not used