Bit Switches - 3
D702 88 SM
Communication Switch 0A (SP No. 1-104-011)
No Function Comments
0
Point of resumption of memory
transmission upon redialing
0: From the error page
1: From page 1
0: The transmission begins from the page
where transmission failed the previous time.
1: Transmission begins from the first page,
using normal memory transmission.
Communication Switch 0B (SP No. 1-104-012)
No Function Comments
4
Printout of the message when
acting as a Transfer Station
0: Disabled, 1: Enabled
When the machine is acting as a Transfer
Station, this bit determines whether the
machine prints the fax message coming in
from the Requesting Terminal.
Communication Switch 0D (SP No. 1-104-014)
No Function Comments
0-7
The available memory
threshold, below which ringing
detection (and therefore
reception into memory) is
disabled
00 to FF (Hex), unit = 4 kbytes
(e.g., 06(H) = 24 kbytes)
One page is about 24 kbytes.
The machine refers to this setting before each
fax reception. If the amount of remaining memory
is below this threshold, the machine cannot
receive any fax messages.
If this setting is kept at 0, the machine will detect
ringing signals and go into receive mode even if
there is no memory available. This will result in
communication failure.
Communication Switch 0E (SP No. 1-104-015)
No Function Comments
0-7
Minimum interval between
automatic dialing attempts
06 to FF (Hex), unit = 2 s
(e.g., 06(H) = 12 s)
This value is the minimum time that the machine
waits before it dials the next destination.