Settings for @Remote Service
M160/M161 2-80 SM
2.21 SETTINGS FOR @REMOTE SERVICE
Prepare and check the following check points before you visit the customer site. For
details, ask the @Remote key person.
2.21.1 CHECK POINTS BEFORE MAKING @REMOTE SETTINGS
1. The setting of SP5816-201 in the mainframe must be "0".
2. Print the SMC with SP5990-002 and then check if a device ID2 (SP5811-003) must be
correctly programmed.
6 spaces must be put between the 3-digit prefix and the following 8-digit number (e.g.
xxx______xxxxxxxx).
3. The following settings must be correctly programmed.
4. If a proxy server is available, configure the following SP settings.
Use Proxy (SP5816-062) Set to "1: Enable".
Proxy server IP address (SP5816-063)
Proxy server Port number (SP5816-064)
Proxy User ID (SP5816-065)
Proxy Password (SP5816-066)
5. Get a Request Number