EasyManua.ls Logo

Ricoh M160 - Sram Data Transfer Procedure

Ricoh M160
836 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FCU
SM 4 M160/M161 Fax Option
2. REPLACEMENT AND ADJUSTMENT
2.1 FCU
2.1.1 SRAM DATA TRANSFER PROCEDURE
When you replace the FCU board, transfer the SRAM data from the old FCU board to the new
FCU board. Do the following procedure to back up the SRAM data.
The following data can be transferred: TTI, RTI, CSI, Fax bit switch settings, RAM
address settings, NCU parameter settings
1. Open the front cover.
2. Open the rear cover.
3. Remove the right cover [A] (
x 4, hook x 3).
4. Remove the five screws of the bracket [A] (
x 5), and then, remove the FCU board [B]
with bracket (
x 1, x 1)