6.2.5 SC400 (IMAGE PROCESSING – 2)
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC440-00 D
High voltage output error: Transfer unit
This SC is issued if the BICU detects a short in the power pack
10 times consecutively.
Open circuit (+) / Short circuit (-)
Turn the main power OFF and then ON.
Replace the controller board.
Check the connector connection.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC498-00 C
Temperature/humidity Sensor error
Temperature sensor output error: Out of range between
0.76 V and 2.90 V
Humidity sensor output error: 2.4 V or more
Unmounted sensor (Disconnected connector or broken
wire)
Failed sensor
Turn the main power OFF and then ON.
Check that the connector is set.
Set the sensor.
Replace the sensor.
Replace the connector.