Main SP Tables-7
SM Appendix 3-147 M160/M161
Appendices:
SP Mode Tables
3.8 MAIN SP TABLES-7
3.8.1 SP7-XXX (DATA LOG)
7401
[Total SC]
Stores total SC occurring count.
If the same SC codes are detected continuously and total counter is not
increasing, it only logs once in case of deleting other SC code logs.
7-401-001 SC Counter C*
[0 to 65535 / - / 1/step]
7-401-002 Total SC Counter C*
7403
[SC History]
Logs and displays the SC codes detected.
The 10 most recently detected SC Codes are displayed on the screen, and
also can be seen on the SMC (logging) outputs.
If the same SC codes are detected continuously and total counter
is not increasing, it only logs once in case of deleting other SC
code logs.
7-403-001 Latest C*
[0 to 65535 / - / 1/step]
7-403-002 Latest 1 C*
7-403-003 Latest 2 C*
7-403-004 Latest 3 C*
7-403-005 Latest 4 C*
7-403-006 Latest 5 C*
[0 to 65535 / - / 1/step]
7-403-007 Latest 6 C*
7-403-008 Latest 7 C*
7-403-009 Latest 8 C*
7-403-010 Latest 9 C*

Table of Contents