Troubleshooting
M160/M161 6-116 SM
Registration
A: Leading edge registration
B: Side-to-side registration
1. Place the test chart on the exposure glass and make a copy from one of the paper feed
trays.
2. Check the leading edge and side-to-side registration, and adjust as necessary with the
following SP modes.
Name SP No. Specification
L-Edge Regist Adjustment SP4-010-001 0 ± 2mm
S-to-S Regist Adjustment SP4-011-001 0 ± 2.5mm
ARDF Image Adjustment
Registration
Use "Test Chart" to adjust this setting.
1. Place the temporary test chart on the ARDF and make a copy from one of the paper
feed trays.
2. Check the registrations, and adjust as necessary with the appropriate SP modes, as
follows.