SC No. Level Error Name/Error Condition/Major Cause/Solution
SC144 D
SBU Communication Error
Cannot correctly establish communication with the SBU.
Defective harness
Defective destination device (e.g., BICU, etc)
Defective SBU
Reboot the machine.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC161-01 D
IPU error (LSYNC error)
When turning the power on or when recovering from energy
saving mode, the machine performs a BICU self-diagnostic test.
If it detects an error, it reports an IPU (LSUNC) error.
Defective IPU or BICU (or bad connection between the
ASIC and the LEO, LSYNC Abnormal, etc)
Faulty cable connection between the SBU and IPU (or
BICU).
Check the connection between SBU and IPU (BICU)
Replace the IPU (BICU)
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC161-02 D
IPU error (RI response error)
Detecting an error on access to the RI.
Defective IPU (BICU, ICTL) or RI abnormal performance, etc
Replace the IPU (BICU)