EasyManua.ls Logo

Ricoh M160 - Page 260

Ricoh M160
836 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service Call
M160/M161 6-16 SM
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC544-00 A
Fusing (Center) thermopile high-temperature detected
(hardware)
The hardware high-temperature error sensor flag is detected.
Damaged triac (shorted)
Failed engine control board
Failed fusing thermopile
Failed fusing thermistor
Abnormal fusing control software behavior
The PWM signal is continuously supplied from the IH
inverter (due to a software or temperature sensor error).
Clear the SP: fusing SC.
Replace the PSU.
Replace the Engine Board.
Replace the fusing thermopile.
Replace the Fusing Unit.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC545-00 A
Fusing (Center) lamp stays ON
The thermistor (center) has not detected the target temperature,
even after the fusing lamp stays ON for more than 30 seconds
after reloading.
Deformed or floating thermistor
Broken fusing lamp wire
The overtemperature prevention mechanism started
working
Clear the SP: fusing SC.
Replace the fusing thermistor.
Replace the fusing (Center) lamp.

Table of Contents

Related product manuals