Service Call
SM 6-19 M160/M161
Troubleshooting
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC554-00 A
Fusing (End) thermistor high-temperature detected (hardware)
The hardware high-temperature error sensor flag is detected.
Damaged triac (shorted)
Failed engine control board
Failed fusing thermopile
Failed fusing thermistor
Abnormal fusing control software behavior
The PWM signal is continuously supplied from the IH
inverter (due to a software or temperature sensor error).
Clear the SP: fusing SC.
Replace the PSU.
Replace the Engine Board.
Replace the fusing thermopile.
Replace the Fusing Unit.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC557-00 C
Zero-crossing frequency exceeded
The number of zero-crossing interrupts exceeds a certain value
in 500 ms.
The frequency of the commercial power supply line is unstable
or noise occurs.
None