Service Call
M160/M161 6-98 SM
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC876-02 D
Log Data Error 2
An error was detected in the acquisition or configuration of the
log data at power on or during machine operation.
Log encryption is enabled but encryption module is not installed.
Replace or re-install the encryption module.
Disable the log encryption setting.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC876-03 D
Log Data Error 3
An error was detected in the acquisition or configuration of the
log data at power on or during machine operation.
Inconsistency of encryption key between NV-RAM and HDD.
Disable the log encryption setting.
Initialize LCS memory (SP5801-019).
Initialize the HDD (SP5-832-004).
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC876-04 D
Log Data Error 4
An error was detected in the acquisition or configuration of the
log data at power on or during machine operation.
Log encryption key is disabled but the log data file is
encrypted.(NVRAM data corruption)
Log encryption key is enabled but the log data file is not
encrypted.(NVRAM data corruption)
Initialize the HDD (SP5-832-004).
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC876-05 D Log Data Error 5