Main SP Tables-2
M160/M161 3-18 SM Appendix
2-301-103 Used Adjust A4 E*
[0 to 100 / 65 / 1%/step]
Output adjustment for the value of the
transfer output table which is to be a
basis when the transfer paper count is
in the range of 60K and 90K.
2-301-104 Used Adjust A5 E*
[0 to 100 / 60 / 1%/step]
Output adjustment for the value of the
transfer output table which is to be a
basis when the transfer paper count is
over 90K.
2401 [Timing Control]
2-401-003 T[rotation print] E* [600 to 9900 / 600 / 100msec/step]
2-401-004 T[rotation WU] E* [600 to 9900 / 5000 / 100msec/step]
2411 [envi_section]
2-411-001 AH_LM E*
[0.0 to 10.0 / 5.5 / 0.5g/m
3
/step]
Displays and adjusts the threshold
under low/mid humidity on environment
section in regard to control the
Environment Correction.
2-411-002 AH_MH E*
[11.0 to 30.0 / 15.0 / 0.5g/m
3
/step]
Displays and adjusts the threshold
under mid/high humidity on
environment section in regard to control
the Environment Correction.
2924
[Supply Speed]
For circulating the time to supply certain amount
2-924-001 Remaining H:240 E* [0.01 to 1.00 / 0.35 / 0.01g/sec/step]
2-924-002 Remaining M:240 E* [0.01 to 1.00 / 0.29 / 0.01g/sec/step]
2-924-003 Remaining L:240 E* [0.01 to 1.00 / 0.22 / 0.01g/sec/step]