Main SP Tables-5
SM Appendix 3-129 M160/M161
Appendices:
SP Mode Tables
5-849-003 Total Counter C*
[0 to 99999999 / 0 / 1/step]
Displays the total counts at the installed
date (SP5-849-001).
5851 [Bluetooth]
5-851-001 Mode C*
[0 or 1 / 0 / 1/step]
Sets the operation mode for the
Bluetooth Unit.
0: Public
1: Private
5856
[Remote ROM Update]
Allows reception of firmware data via the local port (IEEE 1284) during a
remote ROM update, when the value set to “1”. This setting is reset to “0”
after the machine is cycled off and on. Allows the technician to upgrade the
firmware using a parallel cable.
5-856-002 Local Port C*
[0 or 1 / 0 / 1/step]
0: Disable
1: Enable
5857 [Save Debug Log]
5-857-001 On/Off C*
[0 or 1 / 0 / 1 / -]
0: OFF
1: ON
Switches on the debug log feature. The
debug log cannot be captured until this
feature is switched on.
5-857-002 Target (2:HDD 3:SD) C*
[ 1 to 3 / 2 / 1/step]
1: IC Card
2: HDD
3: SD Card
Selects the destination where the
debugging information generated by
the event selected by SP5-858 will be
stored if an error is generated.

Table of Contents