Bit Switches - 4
SM 98 M160/M161 Fax Option
G3 Switch 0F (SP No. 1-105-016)
No Function Comments
0
Alarm when an error occurred
in Phase C or later
0: Disabled
1: Enabled
If the customer wants to hear an alarm after each
error communication, change this bit to "1".
1
Alarm when the handset is
off-hook at the end of
communication
0: Disabled
1: Enabled
If the customer wants to hear an alarm if the
handset is off-hook at the end of fax
communication, change this bit to "1".
2-3 Not used Do not change these settings.
4
Sidaa manual calibration
setting
0: Off
1: On
1: manually calibrates for communication with a
line whose current change occurs such as an
optical fiber line.
6 Not used Do not change this setting.